www.acti.com
TCM-7811 Hardware Users Manual
11
3) Power Input
Connect the power adaptor here if your power input is DC12V.
4) CDS Sensor
CDS Sensor detects the level of lighting in the environment, and helps the camera decide between
day and night modes.
5) Ethernet Port
The IP device connects to the Ethernet via a standard RJ45 connector. Supporting NWAY, this IP
device can auto detect the speed of local network segment (10Base-T/100Base-TX Ethernet).
Pin Name
Description
Spec
DIO PW
Electrically connected in parallel with the con-
nector for the power supply, this pin provides an
auxiliary connector for mains power to the unit.
This pin can also be used to power auxiliary
equipment, with a maximum current of 100mA.
Voltage: 12V DC,
Max: 1.2W
DIO GND
Ground
DO
(Transistor
Output)
Uses an open-collector NPN transistor with the
emitter connected to the GND pin. If used with an
external relay, a diode must be connected in
parallel with the load, for protection against
transient voltages.
Max load = <100mA
Max voltage = 24V
DC (to the
transistor)
DI
(Digital
Input)
Connect to GND to activate, or leave floating (or
unconnected) to deactivate.
Must not be
exposed to
voltages greater
than 30V DC.
PIN
NAME
1
12V
2
GND