ACTi E66 Installationsanleitung

Stöbern Sie online oder laden Sie Installationsanleitung nach Sicherheitskameras ACTi E66 herunter. ACTi E66 Installation guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
E-1
WARNING
• When inserting the PS-3700A(Eden
ESP6000-667MHz Model) (hereafter referred to as the
"PS-A")'s power cord into the PS-A's AC Connector, check first that the PS-A's power supply is
completely turned OFF, via a breaker, or similar unit.
• Before either plugging in or unplugging a board or interface connector, be sure to turn the PS-As
power OFF.
• Whenever changing the Backlight, to prevent electric shocks and burns, be sure to turn OFF the
PS-A's power and wear protective gloves.
• After the PS-As backlight burns out, unlike the PS-As “Standby Mode”, the touch panel is still
active. If the operator fails to notice that the backlight is burned out and touches the panel, a
potentially dangerous machine operation error can occur.
If your PS-A's backlight suddenly turns OFF, use the following steps to determine if the back-
light is actually burned out.
1) If your PS-A is not set to "Standby Mode" and the screen has gone blank, your backlight is
burned out.
2) Or, if your PS-A is set to Standby Mode, but touching the screen does not cause the
display to reappear, your backlight is burned out.
• Do not open or remodel the PS-A unit, since it may lead to a fire or electric shock.
• Do not use power beyond the PS-A's specified voltage range. Doing so may cause a fire or an
electric shock.
• Do not use the PS-A in an environment where flammable gases are present, since operating the
PS-A may cause an explosion.
• The PS-A uses a lithium battery for backing up its internal clock data. If the battery is incorrectly
replaced (i.e. its + and - sides are reversed), the battery may explode. When changing the
battery, please contact your local PS-A distributor.
• Do not use the PS-A unit as a warning device for critical alarms that can cause serious operator
injury, machine damage or production stoppage. Critical alarm indicators and their control/acti-
vator units must be designed using stand-alone hardware and/or mechanical interlocks.
• To prevent operator injury or machine damage, be sure to design your machine operation system
so that the machine will not malfunction due to a communication fault between the PS-A and its
host controller.
• Do not use PS-A touch panel switches in life-related or important disaster prevention situations. For
safety related switches, such as an emergency switch, be sure to use a separate mechanical switch.
• The PS-A is not appropriate for use with aircraft control devices, aerospace equipment, central
trunk data transmission (communication) devices, nuclear power control devices, or medical
life support equipment, due to these devices inherent requirements of extremely high levels of
safety and reliability.
• When using the PS-A with transportation vehicles (trains, cars and ships), disaster and crime
prevention devices, various types of safety equipment, non-life support related medical devices,
etc. redundant and/or failsafe system designs should be used to ensure the proper degree of
reliability and safety.
WARNINGS
To prevent this unit from malfunctioning :
• In order to extend the lifetime of the hard disk, Pro-face recommends you set the Windows [Con-
trol panel]-[Power Management option]-[Turn off hard disks] selection to turn the hard disk off
when the unit is not being operated. A setting of 5 minutes is recommended.
• Do not strike the PS-A's touch panel with a hard or heavy object, or press on the touch panel with
excessive force, since it may damage the display.
• Do not install the PS-A where the temperature will exceed its specified range.
• Be sure that water, liquids or metal particles do not enter the PS-A, since it may cause a malfunc-
tion or a short circuit.
• Avoid installing the PS-A where sudden, large changes in temperature may occur. These changes
may cause condensation to form inside the unit, possibly causing a malfunction.
• To prevent excessive heat from building up inside the PS-A, do not install it where its ventilation
holes may be blocked. Also, do not install or store the PS-A near high temperature equipment.
• Do not install or store the PS-A in direct sunlight or where high levels of dust exist.
• Since the PS-A is a precision instrument, do not install or store it where either strong shocks or
excessive vibration may occur.
• Do not install or store the PS-A in an area containing chemicals or chemical fumes.
• Do not use paint thinner or organic solvents to clean the PS-A's case or screen.
• Due to the danger of unforeseeable accidents, back up all PS-A data regularly.
• After turning this unit OFF, be sure to wait a few seconds before turning it ON again. If the unit is
started too soon, it may not start up correctly.
Seitenansicht 0
1 2 3 4 5 6 ... 19 20

Inhaltsverzeichnis

Seite 1 - WARNINGS

E-1WARNING• When inserting the PS-3700A(Eden™ ESP6000-667MHz Model) (hereafter referred to as the"PS-A")'s power cord into the PS-A&apo

Seite 2 - UL/CSA Application Notes

E-10 SwitchesThe following switch settings corresponding to each Serial Interface need to besignified. To set the switches, remove the PS-A’s Re

Seite 3 - Package Contents

E-11TXDRTSSW4SW5SW7SW6SW8TXATXBRXACOM3RXBTable (1) DIPSW1("When using USB" are the DIPSW1 factory settings.)DIPSW2 (SW4 to SW8) in the abov

Seite 4 - About The Manual

E-12Keyboard / Mouse InterfacePS/2 compatible Keyboard / Mouse Interface Ethernet Interface (10BASE-T / 100BASE-TX)This interface complies w

Seite 5 - 1 Part Names

E-13 USB InterfaceThis interface is for connecting USB compatible devices.The USB port on the unit's Front face is USB Ver. 1.1 compatible.T

Seite 6 - 2 Dimensions

E-14• Do not tighten the screws with too much force, since it can damagethe PS-A unit.• The torque necessary to create a drip-resistant seal is 0.5 N•

Seite 7 - 3 General Specifications

E-15• To enhance the PS-A's maintainability, operability and ventilation, allowat least 50 mm clearance between the PS-A and other objects. (Thec

Seite 8 -  Structural

E-16Removing and Installing the Rear Cover• Use a screwdriver to loosen or tighten the screws. Be sure not totighten screws too tightly, since i

Seite 9

E-17 AttachmentAs shown below, insert the USB Cable Clamp’s band through the Bridge. Pass the USB cablesthrough the Cable Clamp’s band and secure

Seite 10

E-18 Installing the AC Power Cord Clamp• Be sure to connect the power cord only after confirming that the PS-A unit rear face power switch is

Seite 11

E-19• If the power supply voltage exceeds the PS-A unit's range, connect avoltage transformer.• Between the line and the ground, be sure to use a

Seite 12

E-2The PS3700A-T41-ASU-E66 is a UL/CSA listed product (UL File No. E220851). Please pay specialattention to the following instructions when applying f

Seite 13 - 5 Installation

E-2010 Replacing the Backlight9 Input/Output Signal Line Cautions• Input and Output signal lines must be separated from the power control cablesfor op

Seite 14 - [11.12 ]

E-3The following items are included in the PS-A's package. Before using the PS-A, please confirm that allitems listed here are present.This unit

Seite 15 - 75[2.95]

E-4The PS-A unit's CD-ROM contains the following PDF manual files.- PS-3700A (EdenTM ESP6000-667MHz Model) User Manual (psae6e.pdf)- PS Series Ty

Seite 16 - Lower USB Connecto

E-51 Part Names1 : Display / Touch Panel2 : Power Lamp LED (POWER)101121514181621201922347111317232425262728 29TopBottomSideRearFront256LED PS-A Statu

Seite 17 - Strap Clip

E-6Unit:mm [in]2 DimensionsFrontTop100 [3.94]282 [11.10]5 [0.20]395 [15.55]294 [11.57]383 [15.08]Side• Prior to attaching peripheral units to the PS-A

Seite 18 - 6 Wiring

E-7 Electrical Environment3 General Specifications• When using any of the PS-A’s optional devices, be sure to checkthat device’s specificati

Seite 19 - 7 Power Supply Cautions

E-8• The Hard Disk lifetime given here may be reduced due to unfore-seen environmental factors, however, generally speaking, the diskshould last for 2

Seite 20 - 8 Grounding Cautions

E-9 Serial Interface (COM1,COM2,COM3,COM4) RS-232C Interface (COM1, COM2, COM3, COM4)15694 InterfacesPin Arrangement PIN# Signal Condition D

Kommentare zu diesen Handbüchern

Keine Kommentare