Acti Edge Recorder Client for Windows V1.0.03 Bedienungsanleitung Seite 33

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 49
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 32
www.acti.com
ACTi Edge Recorder User’s Manual
33
3. To start configuring motions regions here, click Motion Setup”.
4. check Motion Enableand check an MD, its detection region frame will appear on the
mini live view. When the setting is finished, click Apply” to save, and then Closeto exit
this page.
Field Name
Description
Sensitivity(1-100)
Determines how sensitive the camera reacts to the movement. The
higher the sensitivity level is, the smaller the motion will trigger the alarm,
but may give false alarms. Default is 70.
Timer(0-300 secs)
The interval before the next motion detection can be triggered again.
Default is 1 second.
Threshold (%)
The threshold level of this motion detection region. The lower the
threshold level is, the smaller the portion of the region would be
considered as motions, which is more easily to be triggered, but may give
more false alarms.
Note
To move the entire frame
Place the mouse cursor over the title
bar, and drag to move.
To adjust the region dimension
Place the mouse cursor over the
downright corner, and drag to
resize.
To disable this detection region
Place the mouse cursor over the
upper right corner, and click the
“X” to close this frame.
Note
If you have changed the motion detection settings via the web configurator, please remember to
come back to ERC and click Get Device Settings, and then Apply to save. This is to ensure
that the settings in ERC are always in sync with the device.